User Tools

Site Tools


xrvsmr

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Last revisionBoth sides next revision
xrvsmr [2024/06/17 12:34] wadminxrvsmr [2024/06/17 12:48] wadmin
Line 68: Line 68:
   * Measure RTA and store   * Measure RTA and store
  
-== -12dBfs / G=18dB ==+== -12dBfs / G=28dB ==
   * Set Inputs Gain to 28dB   * Set Inputs Gain to 28dB
   * Set Output level to match a -12dBfs input level   * Set Output level to match a -12dBfs input level
Line 80: Line 80:
  
 {{drawio>xrmr:t21.png}} {{drawio>xrmr:t21.png}}
 +
 +=== *R18 Procedure ===
 +
 +== -12dBfs / G=0 ==
 +  * Set Inputs Gain to 0dB
 +  * Set Output level to match a -12dBfs input level
 +  * Measure Transfer function and store
 +
 +== -20dBfs / G=0 ==
 +  * Set Inputs Gain to 0dB
 +  * Set Output level to match a -20dBfs input level
 +  * Measure Transfer function and store
 +
 +== -12dBfs / G=8dB ==
 +  * Set Inputs Gain to 8dB
 +  * Set Output level to match a -12dBfs input level
 +  * Measure Transfer function and store
 +
 +== -12dBfs / G=18dB ==
 +  * Set Inputs Gain to 18dB
 +  * Set Output level to match a -12dBfs input level
 +  * Measure Transfer function and store
 +
 +== -12dBfs / G=28dB ==
 +  * Set Inputs Gain to 28dB
 +  * Set Output level to match a -12dBfs input level
 +  * Measure Transfer function and store
 +
xrvsmr.txt · Last modified: 2024/06/17 12:51 by wadmin