Line 68: | Line 68: | ||
* Measure RTA and store | * Measure RTA and store | ||
- | == -12dBfs / G=18dB == | + | == -12dBfs / G=28dB == |
* Set Inputs Gain to 28dB | * Set Inputs Gain to 28dB | ||
* Set Output level to match a -12dBfs input level | * Set Output level to match a -12dBfs input level | ||
Line 80: | Line 80: | ||
{{drawio> | {{drawio> | ||
+ | |||
+ | === *R18 Procedure === | ||
+ | |||
+ | == -12dBfs / G=0 == | ||
+ | * Set Inputs Gain to 0dB | ||
+ | * Set Output level to match a -12dBfs input level | ||
+ | * Measure Transfer function and store | ||
+ | |||
+ | == -20dBfs / G=0 == | ||
+ | * Set Inputs Gain to 0dB | ||
+ | * Set Output level to match a -20dBfs input level | ||
+ | * Measure Transfer function and store | ||
+ | |||
+ | == -12dBfs / G=8dB == | ||
+ | * Set Inputs Gain to 8dB | ||
+ | * Set Output level to match a -12dBfs input level | ||
+ | * Measure Transfer function and store | ||
+ | |||
+ | == -12dBfs / G=18dB == | ||
+ | * Set Inputs Gain to 18dB | ||
+ | * Set Output level to match a -12dBfs input level | ||
+ | * Measure Transfer function and store | ||
+ | |||
+ | == -12dBfs / G=28dB == | ||
+ | * Set Inputs Gain to 28dB | ||
+ | * Set Output level to match a -12dBfs input level | ||
+ | * Measure Transfer function and store | ||
+ |
xrvsmr.txt · Last modified: 2024/06/17 12:51 by wadmin